Lipid Laboratory – Aquatic Research Cluster (ARC) – CREAIT Network

Research Facility



Lipid Laboratory - Aquatic Research Cluster (ARC) - CREAIT Network
Memorial University
St John's
Newfoundland and Labrador (NL)
The Aquatic Research Cluster (ARC) provides analytical research facilities and support services for determination of lipids and carbon and nitrogen content of aquatic samples to faculty researchers, undergraduate and graduate students and postdoctoral fellows within the University, as well as to government agencies and private sector R&D companies.  ARC currently has analytical laboratories specializing in the determination of organic compounds (lipids and amino acids) and elements (carbon and nitrogen) in samples from the aquatic environment. The lipid lab has instrumentation for performing extractions, thin layer chromatography (TLC), and gas chromatography (GC). The C/N lab has instrumentation for determining dissolved and particulate organic carbon and nitrogen (DOC, POC, DON, PON). Samples may be submitted to be run by the ARC staff, or users may process their own samples, in which case training will be provided by ARC staff.
 
 
 
  • Biological and Life Sciences
  • Chemistry and Biochemistry
  • Engineering - Chemical, Nuclear, Other
  • Environmental and Earth Sciences
  • Marine/Ocean Sciences
  • Biotechnology
  • Education
  • Energy (Renewable and Fossil)
  • Fisheries and Aquaculture
  • Ocean Industries

Contacts



Jeanette Wells
wellsj@mun.ca
7098642521
Research Laboratory Coordinator – Aquatic Research Cluster (ARC)
Brent Myron
7098646798
Manager of Operations – Core Research Equipment and Instrument Training (CREAIT) Network

Equipment



Iatroscan MK-6
Iatron
MK6

The Iatroscan is routinely used to measure lipid classes.

  • Equipped with both FID and FPD detectors.
  • The FID is used for determination of organic compounds
  • The FPD is used for the determination of phosphorous and sulphur
  • Both the FID and FPD can be used simultaneously. 
  • Software used is Peak Simple
2012

Agilent 6890 GC FID
Agilent
6890

The GC is used to quantify fatty acids.

  • Equipped with an 7683 auto sampler.
  • The injector is normally set up for 320 μm capillary columns, but can be changed to fit other columns.
  • The injector is temperature programmable and configured for on-column injection
  • Software used is Agilent OpenLAB CDS
1997

Varian CP-3800 GC FID
Varian
CP-3800

This instrument is used for amino acid and sterol analyses.

  • Equipped with a CP-8400 auto sampler.
  • The injector type is split/splitless. 
  • Software used is Agilent OpenLAB CDS
2007

Agilent 7890B GC FID
Agilent
7890B

This is a multi use instrument

  • Equipped with a 7693A auto sampler.
  • The injector type is a temperature programmable multi-mode inlet. 
  • Software used is Agilent OpenLAB CDS
2018

Perkin-Elmer 2400 Series II CHN analyzer
Perkin-Elmer
2400 Series II

The analyzer gives values for carbon, nitrogen and hydrogen in particulate samples.

The analyzer is equipped with an auto sampler that will hold 60 samples.

2002

Shimadzu TOC/TN analyzer
Shimadzu
TOC-VCPH

The analyzer can measure total carbon (TC), inorganic carbon (IC), non-purgeable organic carbon (NPOC), purgeable organic carbon (POC), and total nitrogen (TN). 

The instrument is equipped with a 48 sample auto sampler.

2002

Date submitted: Mon, Oct 1, 2018 9:54 AM
Date updated: Wed, Oct 3, 2018 7:08 PM

2018-10-03T19:09:27+00:00